Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
3.
Coluna/Columna ; 18(3): 226-230, July-Sept. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019783

ABSTRACT

ABSTRACT Objective The use of pedicle screws was a milestone for modern spinal surgery. This type of fixation, due to its superior biomechanics, gave greater fixation power, greater capacity to withstand the pulling forces and, therefore, greater stability and lower rates of pseudoarthrosis. Fixation of the lumbosacral junction, even with the development of these new implants, remains a challenge mainly because the considerable rates of pseudoarthrosis. The use of iliac screws solves the biomechanical difficulties. However, its use shows high rates of surgical wound problems. The S2-Alar-Iliac screw (S2AI) came as a solution to these complications. The lack of studies about anatomical and anthropometric parameters in the Brazilian population justifies the study. Methods Eleven hip tomographies of Brazilian adult males were analyzed by four evaluators. The right and left sides were considered. In each patient, measurements were made of greater and shorter bone length, greater and smaller bone diameter, distance from the entry point to the skin, sagittal and axial angles related to the hypothetical insertion of an S2AI screw and compared to the same measurements obtained with the iliac screw. Results The mean bone length was 136.7 mm, the greatest bone diameter was 24.8 mm, the smallest bone diameter was 19.7 mm and the distance from the screw to the skin was 42.1 mm for the S2AI screw. Conclusions The obtained data present an average of the sample that can be useful in the decision of the surgical technique in the studied group. Level of evidence I; Diagnostic Studies (Anatomical Investigation).


RESUMO Objetivo O uso de parafusos pediculares foi um marco para a cirurgia moderna de coluna vertebral. Esse tipo de fixação, devido a sua biomecânica superior, deu maior poder de fixação, maior capacidade de resistir às forças de arrancamento e, portanto, maior estabilidade e menores taxas de pseudoartrose. A fixação da junção lombossacra, mesmo com o desenvolvimento destes novos implantes, permanece um desafio devido, principalmente, às consideráveis taxas de pseudoartrose. O uso de parafusos de ilíaco resolve o problema biomecânico. Entretanto, seu uso mostra elevadas taxas de problemas na ferida operatória. O parafuso de S2-Alar-Ilíaco (S2AI) veio como solução para essas complicações. A falta de estudos acerca dos parâmetros anatômicos e antropométricos na população brasileira justifica o estudo realizado. Métodos Foram analisadas 11 tomografias de bacia de homens brasileiros adultos por 4 avaliadores. Foram considerados os lados direito e esquerdo. Em cada paciente foram feitas medidas de maior e menor comprimento ósseo, maior e menor diâmetro ósseo, distância do ponto de entrada na pele, ângulos sagital e axial relacionadas à hipotética inserção de um parafuso S2AI e comparadas às mesmas medidas obtidas em relação ao parafuso de ilíaco. Resultados O comprimento ósseo médio foi de 136,7 mm, maior diâmetro ósseo foi de 24,8 mm, o menor diâmetro ósseo de 19,7 mm e a distância do parafuso para a pele foi de 42,1 mm para o parafuso S2AI. Conclusão Os dados obtidos apresentam uma média da amostra que podem ser úteis na decisão da técnica cirúrgica no grupo estudado. Nível de evidência I; Estudo Diagnóstico (Investigação Anatômica).


RESUMEN Objetivo El uso de tornillos pediculares fue un marco para la cirugía moderna de la columna vertebral. Este tipo de fijación, debido a su biomecánica superior, dio mayor poder de fijación, mayor capacidad de resistir a las fuerzas de tracción y, por lo tanto, mayor estabilidad y menores tasas de pseudoartrosis. La fijación de la unión lumbosacra, incluso con el desarrollo de estos nuevos implantes, sigue siendo un desafío debido principalmente a las considerables tasas de pseudoartrosis. El uso de tornillos ilíacos soluciona el problema biomecánico. Sin embargo, su uso muestra altas tasas de problemas en la herida quirúrgica. El tornillo S2-Alar-Ilíaco (S2AI) vino como solución para estas complicaciones. La falta de estudios sobre los parámetros anatómicos y antropométricos en la población brasileña justifica el estudio realizado. Métodos Se analizaron 11 tomografías de cadera de hombres brasileños adultos por 4 evaluadores, considerando los lados derecho e izquierdo. En cada paciente se realizaron medidas de mayor y menor longitud ósea, mayor y menor diámetro óseo, distancia del punto de entrada en la piel, ángulos sagital y axial relacionados con la inserción hipotética de un tornillo S2AI y comparados a las mismas medidas obtenidas en relación al tornillo ilíaco. Resultados La longitud ósea promedio fue de 136,7 mm, el mayor diámetro óseo fue de 24,8 mm, el diámetro óseo menor de ١٩,٧ mm y la distancia del tornillo a la piel fue de 42,1 mm para el tornillo S2AI. Conclusiones Los datos obtenidos presentan un promedio de la muestra que puede ser útil en la decisión de la técnica quirúrgica en el grupo estudiado. Nivel de evidencia I; Estudios de Diagnósticos (Investigación Anatómica).


Subject(s)
Humans , Spinal Diseases , Anatomy , Lumbosacral Region
4.
Acta ortop. bras ; 25(1): 15-17, Jan.-Feb. 2017. tab
Article in English | LILACS | ID: biblio-837737

ABSTRACT

ABSTRACT Objective: To evaluate the hormonal profile of patients with adolescent idiopathic scoliosis (AIS) and its relationship to the severity of the curvature and quality of life . Method: Patients with scoliosis (Cobb angle above 10°), of both genders, diagnosed after 10 years of age were included, excluding those who presented other condition that could lead to scoliosis. Serum levels of 25-hydroxyvitamin D (25-OHD), cortisol and gastrin were correlated with Cobb angle and quality of life, measured by the SRS-30 questionnaire . Results: The levels of 25-OHD decreased in 97% of patients. There was an inverse relationship between gastrin levels and quality of life (p = 0.016). Moreover, there was an inverse correlation between the value of Cobb angle and quality of life (p = 0.036). There were no changes in cortisol levels. There was no correlation between Cobb angle and any of the hormones measured . Conclusion: The patients had levels of 25-OHD diminished, strengthening the hypothesis of its involvement in the development of AIS. This study also suggests that increased gastrin levels may be associated with a worse quality of life in patients with AIS. Level of Evidence II, Diagnostic Study.


RESUMO Objetivo: Avaliar o perfil hormonal dos pacientes com escoliose idiopática do adolescente (EIA) e sua relação com a gravidade da curvatura e qualidade de vida. Método: Foram incluídos pacientes com escoliose (ângulo de Cobb acima de 10°), de ambos os sexos, diagnosticados após 10 anos de idade e foram excluídos aqueles que apresentassem outra condição que pudesse acarretar em escoliose. Os valores séricos da 25-hidroxivitamina D (25-OHD), cortisol e gastrina foram correlacionados com o ângulo de Cobb e a qualidade de vida, mensurada através do questionário SRS-30. Resultados: Os níveos de 25-OHD estavam reduzidos em 97% dos pacientes. Observou-se uma relação inversa entre níveis de gastrina e a qualidade de vida (p=0,016). Ademais, constatou-se correlação inversa entre o valor do ângulo de Cobb e a qualidade de vida (p=0,036). Não foram observadas alterações nos níveis de cortisol. Não houve correlação do ângulo de Cobb com o nível de nenhum dos hormônios dosados. Conclusão: Os pacientes apresentaram níveis de 25-OHD diminuídos, fortalecendo a hipótese da sua implicação no desenvolvimento da EIA. O presente estudo também sugere que o aumento dos níveis de gastrina possa estar relacionado com pior qualidade de vida nos pacientes com EIA. Nível de Evidência II, Estudo Diagnóstico.

5.
Acta ortop. bras ; 24(1): 35-38, Jan.-Feb. 2016. tab
Article in English | LILACS | ID: lil-771857

ABSTRACT

ABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study.

SELECTION OF CITATIONS
SEARCH DETAIL